 {{ :documents:ngi-5000-logic:bottom_screen_2.jpg?300|}} {{ :documents:ngi-5000-logic:bottom_screen_2.jpg?300|}}
 +Global retard is an adjustment affecting the timing of all cylinders equally. This adjustment
 +can be equated to the manual timing switch of the Altronic II-CPU system. Adjustments
 +made as described below will be in effect until another adjustment is made.
 +
  
 ---- ----
Line 134: Line 138:
 ---- ----
 {{ :documents:ngi-5000-logic:manual_retard.jpg?300|}} {{ :documents:ngi-5000-logic:manual_retard.jpg?300|}}
 +The increment of timing change is dependent on the number of holes or teeth being sensed. 
 +The minimum timing change is equal to "90/N" where N = no. of holes or teeth. EXAMPLE: 
 +For 360 holes, the minimum timing change increment is 90/360 = 0.25 degrees.
 ===== - SELECTION OF GLOABL TIMING MODES ===== ===== - SELECTION OF GLOABL TIMING MODES =====
 {{ :documents:ngi-5000-logic:timing_all.jpg?300|}} {{ :documents:ngi-5000-logic:timing_all.jpg?300|}}
 +Several options exist with regard to global timing modes. Once the global timing mode menu
 +is entered as described below, the status of each option can be viewed and changed.
  
 ---- ----
Line 144: Line 152:
  
 {{ :documents:ngi-5000-logic:one_step_retard.jpg?300|}} {{ :documents:ngi-5000-logic:one_step_retard.jpg?300|}}
 +selection can increase or decrease the one-step retard value. The default 
 +configuration selects one step retard to be controlled by the Misc Input terminal. The 
 +additional retard would be implemented when the input is grounded.
 ---- ----
 {{ :documents:ngi-5000-logic:rpm_retard.jpg?300|}} {{ :documents:ngi-5000-logic:rpm_retard.jpg?300|}}
 +e selection can enable or disable the pre-configured retard curve controlled 
 +internally by engine RPM.
 ---- ----
 {{ :documents:ngi-5000-logic:4-20.jpg?300|}} {{ :documents:ngi-5000-logic:4-20.jpg?300|}}
 +selection can enable or disable the pre-configured retard curve controlled by
 +the 4-20 mA current loop input. The choices are ON and OFF,
  
 ---- ----
 {{ :documents:ngi-5000-logic:serial_retard.jpg?300|}} {{ :documents:ngi-5000-logic:serial_retard.jpg?300|}}
 +selection can enable or disable the additional retard value controlled by the 
 +serial port.
 ===== - SETUP CONTROL OPTIONS ===== ===== - SETUP CONTROL OPTIONS =====
 {{ :documents:ngi-5000-logic:energy_level.jpg?300|}} {{ :documents:ngi-5000-logic:energy_level.jpg?300|}}