documents:ngi-5000-logic:ngi5000operating [2023/02/28 10:16] rocky [5.1 TOP SCREEN] |
documents:ngi-5000-logic:ngi5000operating [2023/02/28 10:23] (current) rocky [8. SELECTION OF GLOABL TIMING MODES] |
||
|---|---|---|---|
| Line 127: | Line 127: | ||
| {{ : | {{ : | ||
| + | Global retard is an adjustment affecting the timing of all cylinders equally. This adjustment | ||
| + | can be equated to the manual timing switch of the Altronic II-CPU system. Adjustments | ||
| + | made as described below will be in effect until another adjustment is made. | ||
| + | |||
| ---- | ---- | ||
| Line 134: | Line 138: | ||
| ---- | ---- | ||
| {{ : | {{ : | ||
| + | The increment of timing change is dependent on the number of holes or teeth being sensed. | ||
| + | The minimum timing change is equal to " | ||
| + | For 360 holes, the minimum timing change increment is 90/360 = 0.25 degrees. | ||
| ===== - SELECTION OF GLOABL TIMING MODES ===== | ===== - SELECTION OF GLOABL TIMING MODES ===== | ||
| {{ : | {{ : | ||
| + | Several options exist with regard to global timing modes. Once the global timing mode menu | ||
| + | is entered as described below, the status of each option can be viewed and changed. | ||
| ---- | ---- | ||
| Line 144: | Line 152: | ||
| {{ : | {{ : | ||
| + | selection can increase or decrease the one-step retard value. The default | ||
| + | configuration selects one step retard to be controlled by the Misc Input terminal. The | ||
| + | additional retard would be implemented when the input is grounded. | ||
| ---- | ---- | ||
| {{ : | {{ : | ||
| + | e selection can enable or disable the pre-configured retard curve controlled | ||
| + | internally by engine RPM. | ||
| ---- | ---- | ||
| {{ : | {{ : | ||
| + | selection can enable or disable the pre-configured retard curve controlled by | ||
| + | the 4-20 mA current loop input. The choices are ON and OFF, | ||
| ---- | ---- | ||
| {{ : | {{ : | ||
| + | selection can enable or disable the additional retard value controlled by the | ||
| + | serial port. | ||